High Frequency DC Portable Dental X-ray

Band nameICLEAR
Model No.CHX-DP10
CertificateIOS CE
Add to Favorites

Quick Details

Tube voltage

60KV

Tube current

1.5mA

Exposure time

0.1--2.0s

Frequency

30KHz

Rate power

60VA

Distance from skin to cone

130mm

Tube focus

0.3mm*0.3mm


Packaging & Delivery

Net weight

2.5KG

Gross weight

3.5KG

Size(mm)

138*165*185

Package size(mm)

365*330*265


Product Description

High Frequency DC Portable Dental X-ray  


CHX-DP10


Characteristics and main use

This portable dental X-ray unit is high frequency machine. The body is small, light weight and nearly no radiation. It has excellent image quality, portable storage, save more space. It uses high frequency and DC international power supply. All of thecomponents installed in the central PC board concentrated. Shock, set-up, electron tubes, all of them are insulation vacuum, sealed stereotype protection. There are also manual buttons installed on the surface of shell, as well as batteries and charges. This unit mainly suitable for oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic equipment, especially for dental implant surgery. It also can connect with sensor, is great convenience.

2.Checking and Security

!  Caution: Please learn relative security measures and functions given in the file or on the unit.

² Using the products after checking battery and the location of the device, make sure that is operates properly.

² Checking all the power cords whether correctly and connected formally.

² Operating the device in the designated order.

² Recheck the cone connect with the patient’s face closely.

² Keep the device and the cone clean.

² Please use or operate the device and parts after taking a necessary periodic inspection.

² If you discover some difference in the sensor images even if you inspected its x-ray exposure time in the same way as before, then it means that the radiation of x-ray isabnormal, you must stop using it immediately and allow it to be inspected.

² Don’t use or store near the place which is possible to fire.

² Don’t use or store where air pressure or temperature or moisture exceeds range.

² Keep good ventilation and avoid direct sunlight, protect against the eroding of dust and corrosive air.

² Don’t use or store near to chemicals or combustible gas.

                    SPECIFICATIONS

 

Tube voltage

60KV

Tube current

1.5mA

Exposure time

0.1--2.0s

Frequency

30KHz

Rate power

60VA

Distance from skin to cone

130mm

Tube focus

0.3mm*0.3mm

Battery

DC14.8V  6400mAh

Charger input voltage

AC100V-240V±10%

Output voltage

DC16.8V

Ambient temperature

5℃~40℃

Relative temperature

<75%RH

Net weight

2.5KG

Gross weight

3.5KG

Size(mm)

138*165*185

Package size(mm)

365*330*265

 